Current Excitation. through screw terminals. Terminal Block National Instruments SCXI -1314 Installation Manual. SCXI chassis- 1001 DAQ device- 1600 module-1520 terminal block-1320 Quarter bridge-I configuration I have connect. connecting RS technology torque convertor to the wiring board of a ni scxi 1314, whats the best way considering that this reads botht the inputChange the type of sensor pressure strain for SCXI-1314. This terminal block includes a factory installed and socketed 350 Ohm quarter-bridge completion resistor for each channel. . x를 어떻게 설정해야 하며, 이 트랜스듀서를 위한. I connected the cable to the S - P + and PIN the SCI QTR 1314. 2) PXI System: PXI-8196 (RT-OS. strain reading system included the acquisition of the signal (SCXI 1314, NI, National Instruments, Austin, Texas, USA), amplifica-. SCXI-1314 Shunt-Calibration Resistors and Quarter-Bridge Resistors R1 RPJ R2 R3 UJ SCB SCB SCB SCB SCA SCA SCA SCA QTR QTR. My sensors are attached to a SCXI-1314 modle in a 1520 box in channel 0 (positioned as in the manual for half bridge) with the completion resistors in the appt places in ch7. com ¥ ni. I am connect a half bridge setting to SCXI-1314 terminal block. The bridgeTerminal Block Compatible SCXI Modules Cabling CJC Special Features TBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-964 Open TC detection isothermal construction, selectable ground referencing TBX-1316 SCXI-1120/D, SCXI-1125, SCXI-1126 SH32-32-A Ð 200:1 attenuation (up to 1,000 VDC)It's seems that the nothing on the system is giving my back accurate data, I must be missing, something in the setup. 0 Kudos Message 7 of 19 (3,305 Views) Reply. . SCXI-1314T. 0 Kudos Message 7 of 9 (8,222 Views) Reply. A probe with an array of V-shaped 3. If you plan to use an SCXI-1104 or SCXI-1125 with a Remote SCXI configuration, you must update the firmware on your SCXI-2000 chassis or SCXI-2400 module. The task has been configured from a full bridge type-I strain gauge with internal excitation. Add to Favourites. Quarter-Bridge Configurations. scxi-1314フロントマウントターミナルブロックのs+とs-に測定対象物を接続します。Hi everybody. The modules hiding behind the 1300 terminal blocks are SCXI 1104C's and the block behind the 1314 (not 1374) is a SCXI-1520. Success Stories. SCXI-1321 Terminal Block. Refer to the SCXI Quick Start Guide to power on the SCXI chassis and configure the system in software. . See how we do it. universal strain with SCXI-1314 terminal block (quantity: 2): This module can simultaneously sample up to 8 channels. Since this is a full bridge sensor, there isn t even any need to change any bridge completion resistors inside the 1314, so it should just be a. . Falls to the side are the leading cause of hip fractures in the elderly. If I wire the output end to S- (negative output) instead of S+, is my result just the card (SCXI-1314, SCXI-1520, SCXI 1000, and PCI-M6221, respec-tively, NI) using Labview 7. Its a simple 4-wire connection Voltage +/- and Sig +/-. 5V excitation), and is connected to a SCXI-1314 terminal block, SCXI-1520 strain gauge module and PXI-6052E DAQ. National Instruments SCXI-1127- 30 W, 60 VA maximum switching power for each channel. SCXI-1129. There are 6 wires in the serial cable. 119. I used the SCXI-1520 Strain. The mobile DAQ system achieves seamless integration among signal conditioning, data acquisition, and synchronization that benchtop instruments would not have achieved. The connector blocks have 3 feet of Belden 8723 signal cables installed on each channel. NI TB-2630 Installation Instructions Manual. what do I need to do to get a reading on my thermistor?SCXI -1314 Installation Manual. Rated 4. I'm using SCXI1102B MOD with a TBX 1314 Accessory. 10. 0 cm by 7. jpg","contentType":"file"},{"name":"10. NI SCXI-1520 strain gauge input; NI SCXI-1314 terminal blocks; Results. The National Instruments SCXI-1102 and SCXI-1112 are designed for high-accuracy thermocouple measurements. Mod9: SCXI-1102 . It also contains instructions for verifying the performance of the temperature sensor for those. Do not connect anything else to the DAQ board. Radwell is not an authorized distributor, reseller or representative of the products featured on this website. This paper discusses the calibration of a custom made force sensor, and its implementation to a multi-axis data acquisition system for an optimal bicycle cranking mechanism. Verifying Gain and Offset Errors The verification procedure determines how well the SCXI-1520 module is meeting its specifications. The SCXI. It was just difficult to see since I was almost standing on my head while trying to read that little number. You may need to have the connector block to SCXI 1520 to connect your sensors to the SCXI 1520. It is showing some flucturaing signal when I click the test icon. Each cantilever sensor is part of a shielded 1/4 Wheatstone bridge configuration. Options. Set the following parameters: • SCXIchassisID—The value assigned by MAX • moduleSlot—1 • moduleChan—The channel number from step 3 • excitationType—2The SCXI-1314 has eight possible channels for strain gage connections. Verify that SCXI-1314 is selected in the Accessories. We use a SHC-68-68EPM cable to connect the DAQcard to the scxi. Part Numbers:187212B-01, 777687-14 SCXI-1127. I had a working VI that could balance a wheatstone half bridge and read and record measurements. 2. The SCXI-1314 and SCXI-1520 was employed with the SCXI-1000 chassis for the torsional measurement of torque tube. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. As you can see in page 4 of the SCXI-1314 manual, both shunt calibration resistors A and B are have a value of 100 kohm. Figure 2. 00. 121. . You would need to have SCXI chassis with SCXI 1349 with 68-68 Pin E-Series DAQ cable (SH68-68-EP) to plug in the SCXI 1520 and connected to the PCI 6036E. . Quarter-Bridge I Circuit Diagram The following symbols apply to the circuit diagram and equationsSCXI-1314 Terminal Block Calibration Procedure - National. 1) Open the DAQ card in MAX and Open the Test Panels. SCXI-1503 SCXI-1306 – SCXI-1520 SCXI-1314 – Quarter-bridge completion/shunt resistor. . 10. (+ SCA x 2) Is it really necessary to do shunt calibration. Part Number: SCXI-1314: Manufacturer/Brand: Equipment: Description: National Instruments 197882A-01 High-Voltage Attenuator Terminal Block: Speak to a sales representative for pricing & lead time: Phone:SCXI- 1000 Chassis w/ 1346 adapter PCI 6281 DAQ card SCXI- 1520 Bridge Board w/ 1314 Terminal Block (x2) SCXI- 1180 Feedthrough Panel w/ 1302 Block Signal Express 2014. We are using a SCXI-1520 with a SCXI-1314 accessory with the intention of using it with some full bridge and half bridge strain gauges. SCXI-1503 SCXI-1306 3 Ð SCXI-1520 SCXI-1314 Ð Quarter-bridge completion/shunt resistor SCXI-1540 SCXI-1315 Ð Ð. Mod7: SCXI-1521B. desktop computer and a National Instruments NI SCXI-1314 analog to digital conversion module. These sensors served primarily as switches for finger task identification during data processing. I have a test where I am measuring several channels of displacement measuring potentiometers, several quarter bridge strain gauges, a. This document also. Diagram of the vi showing a "?" for the icon for the "Analog 1D DBL NChan 1Samp" vi. Relevant NI Products. 777687-14 Front-mounting terminal block for the SCXI-1520 module. SCXI-1520(혹은 PXI-4220)을 사용하려면 Traditional NI-DAQ 혹은 NI-DAQmx 7. SCXI-1001: PXIe-1065: cDAQ 9178 cDAQ. The SCXI-1520 module provides parallel measurement of up to 8-channels simultaneously, capturing and multiplexing into a single data stream to a PC acquisition card (National Instruments, M-Series PC-6221) with a maximum sampling rate of 250 kS/s. 16 pages. 11-14-2009 08:42 AM. The RN-55 style quarter-bridge completion resistors are provided in the SCXI-1314 front-mounting terminal block. 4. Excitation Output Channels. Order toll free: 800. an SCXI-1314 terminal block, connect the DMM to the P0+ and P0– output terminals of the SCXI-1314. Within daqmx I have my range néc - 500 to 3500 uStrain with an excitement of the factor of 10V and pledge of 2. Hello All I am using SCXI 1520 and SCXI 1314 TB in SCXI 1000 chassis with SCXI 1600 USB controller. They are socketed,so you can replace them with your own resistors. Effects of two pre-treatment methods, isothermal annealing and DC-current stressing, on the reliability of solder interconnections under vibration loading has been studied in this paper. 1 as described in the preceding text. SCXI-1314 187212B-01 777687-14. Each SCXI-1000 chassis includes 8-channel SCXI-1520 input modules, which provide a scanning capacity of up to 96 channels for each scanner. Rate the SCXI-1314. 4 Class 2). The SCXI-1314 has eight possible channels for strain gage connections. . 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. -lb (56-79 Newton cm). Win7 Enterprise. A suspicious death, an upscale spiritual retreat, and a quartet of suspects with a motive for murder. The SCXI-1102 also can acquire millivolt, volt, 0 to 20 mA, and 4 to 20 mA current input signals,as well as signals from RTDs when the SCXI-1581 provides excitation. I am using the SCXI-1000 Chassis,SCXI-1349, SCXI-1520, SCXI-1314 and PCI-6023E DAQ card. No other lines should be connected on the terminal block, because that could distrupt the input reading on the channel. Feedthrough Panel and Lowpass Filter Module Wiring of the SCXI-1302 and SCXI-1304 Terminal BlocksB-4 C. we need test 10 pieces of thermocouples ,3 LVDT signals and 3 strain guage at one time. The problem just started after inserting a similar module in the second slot. Analog Output Channel Signal Connections on the SCXI-1124. Attach the SCXI-1317 to the SCXI-1521/B using the thumbscrews. The terminals labeled GND are not used on the SCXI-1162. Figure 4-10. 115. scxi-1161 - - モジュール内にスクリューターミナル装備 scxi-1162/hv scxi-1326 - - scxi-1163/r - scxi-1180 scxi-1302 - 50ピン端子台 scxi-1181 scxi-1300 - scxi-1181k scxi-1301 - - scxi-1520 scxi-1314 - クォータブリッジ構成/シャント抵抗 scxi-1540 scxi-1315 - - scxi-1581 scxi-1300 - -SCXI-1338 Installation Guide 2 ni. The task has been configured from a full bridge type-I strain gauge with internal excitation. . Half-bridge completion is provided in the SCXI-1520, and you can enable it through software. . For a complete description of. 6, NIDAQmx 8. Labview software (Labview 8. SCXI TM SCXI-1520 User Manual SCXI-1520 User Manual May 2009 372583E-01. The task has been configured from a full bridge type-I strain gauge with internal excitation. scxi-1520のプロパティからチャンネルタブを選び、励起電圧を0vに設定します。 2. 1 as described in the preceding text. I'm going to address your last question first. Right click SCXI-1520 and select Properties from the menu that pops up. Please see my Sig for current hardware specs. The NI SCXI-1520 (Part Number: 777966-20, 186338-01) Universal Strain-Gauge Input Module can be utilized with the SCXI-1314 Screw Terminal Block, the SCXI-1310 Connector and Shell Assembly, the TBX-96 DIN-rail mounted Terminal Block, or the SCXI-1314T RJ-50 Terminal Block. their associated screw terminals. 2. zero. In Stock. Figure 6. For an upcoming test we plan to use an old SCXI-1001 chassis, an SCXI-1600 Daq, and 7 SCXI-1520's along with the SCXI-1314's to measure 50+ channels of strain gages. Set the following parameters: • SCXIchassisID—The value assigned by MAX • moduleSlot—1 • moduleChan—The channel number from step 3 • excitationType—2As mentioned, I'm configuring my 1520 and 1314 for 1/4 and full bridge. I have connected two. You also need either the SCXI‑1314 or SCXI‑1314T front mount terminal block to use the SCXI‑1520. When I hook up the strain module to the 6356, it never shows up in MAX. The SCXI-1314 terminal block is used with the SCXI-1520 universal. 8. null-offset. The SCXI-1314T terminal block works with the SCXI-1520 universal strain/bridge sensor module to conveniently connect hardware TEDS smart sensors using RJ-50 10 position/10 conductor (10p10c) modular plugs. jpg","path":"10. All reports are written by real visitors of this website. SCXI-1314. Note When connecting your signals to the SCXI-1327, follow the labeling on the SCXI-1327 for the appropriate module, as indicated in Figure 2. Try searching for what you need. $200. Minimum Repair Price is $200. 신호 입력 터미널(SCXI-1314에서 S+ 및 S-)을 샤시 그라운드에 접지하십시오. 1-do I have to set the gain of the amplifier first( can't see how)and then create the scale or it is not necessary 2-how can I calculate the shunt resistance( I am using 4 resistances of 350 ohm fo. com ¥ ni. My problems are that I am confused on how to exactly wire my strain gauge to the SCXI-1314 and properly calibrate it. The terminal block and strain input module were housed by an NI SCXI 1000 Chassis. The quarter-bridge completion resistor is in the SCXI-1314 terminal block and is socketed. Pdf Manuals software by Title Popularity Freeware Linux Mac. I am using DAQmx Vis to program. Should we attach the ground wires to theThe Wheatstone-bridge used was a half-bridge type called quarter bridge II in the Measurement and Automation Explorer software of National Intrument (NI) strain-bridge ref. Support Worldwide Technical Support and Product Information ni. com Number 1 and 2 Phillips-head screwdrivers 1/8 in. So definitely something is wron. 12 pages. There are. 3–0. Show More Description. Presented by Photography and Floor Plans by CMC Photo and Measure ServicesPhotography | Floor Plans | RMS Measurements | 3D Tours | Video | Drone |. All Products. 9393. I am developing an application to apply the SCXI-1314 shunt resistors to 250 strain gages for calibration. Spy ear is the devices which converts low power audio signal to high power signal and gain. With this system, it is possible to measure only theherein are trademarks or trade names of their respective companies. Figure 1. com Conventions The following conventions are used in this guide: » The » symbol leads you through nested menu items and dialog box options to a final action. SCXI-1314 - 4 nos. 1 SCXI-1000 SCXI-1520 SCXI-1314 PCI-6031E Windows 2000 Greetings- I'm trying to determine how the gain that is settable on a given channel of an SCXI-1520 module is combined with the gain that NI Max assigns to a Virtual Channel. C. . Detailed Name. Clean the module and accessories by brushing off light dust with a soft non-metallic brush. No load applied; In the calibration table of DAQ task in MAX, the sensor showed zero. Phone 2362371314 has a negative user rating. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. ThanksNI SCXI-1304 NI SCXI-1306 NI SCXI-1314 NI SCXI-1315 NI SCXI-1326 NI SCXI-1600. The DC coupled device has 8 analog input channels. It can be used in Theaters , Concert halls, Lecture rooms, Trains, Court houses, Conference rooms, Embassies, Gaming facilities, Recording studios, Aircraft , railways ,bus station etc. It has programmable excitation (0-10V), gain (1-1000), and filters. In addition, the SCXI-1520 system offers a half-bridge completion resistor network in the module and a socketed 350 W quarter-bridge completion resistor. Lift cover from SCXI-1314 front panel breakout board. The connection string would be extensometer---> SCXI-1314 (Terminal)---> SCI 1520 (block 2). Industrial-Grade Solutions Smart Buildings Software Defined Labs Video Surveillance Network Monitoring Services. Then, follow the steps below: 1. Solved: Hello, We're trying to figure out which signal name position to use for our ground wire. SCXI-1520 to SCXI-1314 Half-Bridge Connection. I'm using a SCXI 1000 with 1520 bridge module and 1314 terminal block to acquire strain data from a purpose-built "custom" full bridge device (aka custom load cell from now on). Now, I need to calibrate the extensometer (OFFSET REMOVAL and CALIBRATION of SHUNT). SCXI™ Getting Started with SCXI. scxi-1314 ターミナルブロックからカバーを取り外します。 2. When I try to test the system (I/O board PCI 6052) in MAX (with data mode "Continuous. The task uses a SCXI-1000 chassis with a SCXI-1520 module and a SCXI-1314 terminal block. The NI SCXI 1314 is a strain gauge input terminal block, mainly used with floating signals (the voltage signal is not referred to an absolute reference, such as earth or building ground); if this is how you have signals connected here versus the NI SCXI-1327, then it would explain the behavior difference. 124. Half-bridge completion is provided in the SCXI-1520, and you can enable it through software. 1. I connected the cable to the S - P + and PIN the SCI QTR 1314. If you have an SCXI-2000 chassis, right-click its folder and select Properties. I am assuming that you have a SCXI-1314 terminal block that you are using with the SCXI-1520 strain module. The results obtained show that: (1) isothermal annealing and DC-current stressing both compromise the reliability of interconnections during testing in. The SCXI1000 conditioned signals are. SCXI-1314 Terminal Block Calibration Procedure - National. In detail, you may want to look at SCXI page. We're using a scxi-1000 chassis with the scxi-1520 module and scxi-1314 terminal block. View Photo of missing side panel. 00. Am Getting Inaccurate Readings When Some Channels of the SCXI-1520/SCXI-1314 Are Open Circuits My hardware is :- PCI MIO 16E-1 - 1 no. Page 6 Installing the NI 9935 To connect the NI 9935 to a C Series module, complete the following steps. ni 중고 NI 중고 계측기 중고 DAQ 중고 SCXI 중고 cRIO 중고 PXI 중고 ni중고 NI중고 계측기중고 DAQ중고 SCXI중고 cRI. rev: 3. Note When connecting your signals to the SCXI-1313, follow the labeling on the SCXI-1313 for the appropriate module, as indicated in Figure 2. SCXI Module Wiring A. I had a working VI that could balance a wheatstone half bridge and read and record measurements. Per the SCXI-1314 Terminal Block Calibration Procedure, there are two 100K high precision resistors installed to be used for shunt calibration procedures. . The task uses a SCXI-1000 chassis with a SCXI-1520 module and a SCXI-1314 terminal block. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。SCXI-1320 Terminal Block SCXI-1314. This setup works just fine. View Photo of missing side panel. 3. The SCXI-1314 is a National Instruments Terminal Block with a Compatible Module SCXI-1520 . If you need a specific firmware or series relating to SCXI-1314T, we probably have it. 37DSUB 제작케이블. An important added-value of CREPEC resides in the gathering and sharing of our members’ research infrastructures and expertise. we both want the configuration of the signal conditioning and DAQ device meet our requirements and the low cost,so we select the following configuration: SCXI-1000 SCXI-1520 SCXI-1330(instead of SCXI-1314) SCXI-1540 SCXI-1330(instead of SCXI-1315). The SCXI-1314T terminal block works with the SCXI-1520 universal strain/bridge sensor. No other lines should be connected on the terminal block, because that could distrupt the input reading on the channel. 6, National Instru-ments) provided the necessary. Quarter-Bridge Configurations. SCXI-1308. I am using a load cell of 2 gauge factor and resistance 120 ohms. About This Manual Conventions. Front mounting SCXI-1314 terminal blocks are used together with the input modules to make it possible to connect a variety of instruments for full-bridge and quarter-bride measurements. Specifications All specifications are typical at 25 °C unless otherwise specified. 2. Can anybody help?an SCXI-1314 terminal block, connect the DMM to the P0+ and P0– output terminals of the SCXI-1314. SCXI-1314. . The. It also has a 1120 card w/SCXI 1303 terminal block with type K thermocouple installed. Name. To evaluate injurious loads, while considering relevant energy input and body posture for a sideways fall, a subject-specific cadaveric impact experiment was. Resistance value is 125ohm, GF is 2. Rush Available. This document contains information and step-by-step instructions for verifying the value of the shunt-calibration resistors, the value of the quarter-bridge resistors, and the. While SCXI-1314 is a front-mounting terminal block for the SCXI-1520 module. I'm guessing that channel 2 of your 1314 has a 120 Ohm resistor installed, and the other channels. 115. 4 Class 2). On the stationary side, the six strain signals were carried to an NI SCXI 1314 terminal block that was connected to an NI SCXI 1520 strain input module. The connection string would be extensometer---> SCXI-1314 (Terminal)---> SCI 1520 (block 2). I have the serial cable from the load cell connected to a SCXI-1314, SCXI-1520 Module, SCXI-1000 Chassis, and to a Traditional DAQ Card in the PC. Customers interested in this topic were also interested in the following NI products: LabVIEW Data Acquisition (DAQ) Signal Conditioning For more tutorials, return. The NI SCXI-1520 (Part Number: 777966-20, 186338-01) Universal Strain-Gauge Input Module can be utilized with the SCXI-1314 Screw Terminal Block, the SCXI-1310 Connector and Shell Assembly, the TBX-96 DIN. the "Start Installation" window during the install. Call SCXI_Set_Excitation to set the excitation voltage to the desired value. I am acquiring strain (using AI Strain Gage Vi) from each load cell of the balance. Processing Area: 610 × 305 mm 2 Laser options: 10, 25, 30, 40, 50, and 60 W. 96-Pin Female DIN to 88-Pin Female Screw Terminal, 10 V, PXI Module Mount Terminal Block —The TB-4330 provides an industrial PXI front-mounting Terminal Block for PXIe-4330 PXI Strain/Bridge Input Module. NI Supported Device Terminal Block SCXI-1520 SCXI-1314 PXI-4220 N/A SCXI-1121 SCXI-1320 SCXI-1122 SCXI-1322 SCC-SG24 N/A Related Links: NI-DAQmx Example: Ready-to-Run Strain Measurement NI-DAQmx Example: Digital Filtering with the SCXI-1520 NI-DAQmx Example: Nulling all Channels in a Custom Voltage with Excitation Task. Mod8: SCXI-1521B. Analog Output Channel Signal Connections on the SCXI-1124. The informationThe NI SCXI-1324 (Part Number: 777687-24) is ideal for high-voltage general-purpose switching applications. Strain Gage Wiring of the SCXI. an SCXI-1314 terminal block, connect the DMM to the P0+ and P0– output terminals of the SCXI-1314. SCXI-1314. . Loading/Searching dialog windows. Win7 Enterprise. SCXI 1000 Chassis with SCXI 1600 USB, SCXI 1520 strain gauge module and SCXI 1314 strain terminal block gammalight. Each. Rush Available. item 7 National Instruments NI SCXI-1314 Universal Strain Terminal Block Module Unit National Instruments NI SCXI-1314 Universal Strain Terminal Block Module Unit. The SCXI-1314 (Part Number: 777687-14) is created for use with the SCXI-1520 universal strain/bridge module. Guzman et al. signals, 5 digital I/O / programmable function input (PFI) signals, and the. 777687-14 (SCXI-1314, Front Mounting Terminal Block) $ 239. com. The SCXI-1314 terminal block is used with the SCXI-1520 universal strain/bridge module enabling you to conveniently connect strain gauges through screw terminals. The SCXI platform can be used with the NI-DAQ driver for a variety of applications, including data acquisition and signal conditioning. I have manually enterred each of the modules and its accessory into the NI MAX since it still will not auto. Designed to read a voltage range, this module can also satisfy other. 114. 0 Kudos Message 9 of 24 (7,773 Views) Reply. Check for open ports on the device 3. I'm stuck. 2Recommended for thermocouples; includes isothermal design and high-precision CJC sensor. They have been swapped into various chassis and terminal blocks and fail in. 4. I am using DAQmx Assistant to configure the task and calibrating the SG channels. Contents. Our ISO/IEC 17025:2017 accreditation certifies our capabilities. 2. 7 stars - 1895 reviewsNational Instruments SCXI-1314: 1: Data acquisition controller Computer software: National Instruments SCXI-1600 PC with LabView: 1 1: Table 2 lists the technical information of the strain gauges used. SCXI-1349 cable assembly 4. . Rtds. Front mounting SCXI-1314 terminal blocks are used together with the input modules to make it possible to connect a variety of instruments for full-bridge and quarter-bride measurements. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed;National Instruments SCXI-1314 Terminal Block This National Instruments SCXI-1314 Terminal Block is used and in excellent condition. SCXI-1181K SCXI-1301 Ð Ð SCXI-1520 SCXI-1314 Ð Quarter-bridge completion/shunt resisterFind the National Instruments SCXI-1320 at our website: Click HERE. SCXI-1520으로 트랜스듀서에 전원을 인가하고 응답을 모니터링하려고 합니다. 4. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. With factory-installed and socketed 350 Ω quarter-bridge completion resistors for each channel. JPG 187 KB The SCXI-1520 accepts quarter-, half-, and full-bridge sensors. ref: fkm7845The SCXI-1314 includes a factory installed and socketed 350 Ohm quarter-bridge completion resistor for each channel. 117. Average Delivery 5-20 Days. Current-Loop Resistors Note Refer to the Safety Information and Connecting the Signals sections before removing equipment covers or connecting or disconnecting any signal wires. Connector Accessory for E/M/S Series Devices. Figure 3: Sample Connection Diagram for a Strain Gauge Input TaskChapter 2 Connecting Signals SCXI-1520 Set Bridge Configuration to Transducer SCXI-1314 Quarter Bridge – (gauge) – You must connect Shunt the shunt calibration Cal A wires externally using the terminal block screw connections. We would like to show you a description here but the site won’t allow us. You can configure each SCXI-1304 channel to provide AC or DC coupling of a signal to the SCXI module, and each channel can ground reference a SCXI-1314 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, TERMINAL BLOCK, LOW VOLTAGE 1. Leave jumper W1 on the SCXI-1100 in the factory-default (parking) position. 2) For the SCXI channel to view, use the following convention OB0!sc (n)!md (m)!ch where the letter (n) corresponds to the chassis number in MAX (usually = 1), the letter (m) corresponds to the module number (slot) where the module is located in the chassis, and (ch) represents the channel. Analog Circuitry in the SCXI-1122. system allowed sampling at 12 ms intervals of all force transducers in. •Configure and assemble NI SCXI-1314 modules for data acquisition systems •Support operations at Caltrans SRMD Test Facility and Englekirk Structural Engineering Center Show more Show lessSCXI-1520 to SCXI-1314 Half-Bridge Connection. I am using a load cell of 2 gauge factor and resistance 120 ohms. Half-bridge completion is provided in the SCXI-1520, and you can enable it through software. (+ SCA x 2) Is it really necessary to do shunt calibration. . RJ-50 (10p10c) Modular Plug andThe SCXI-1314 is a National Instruments Terminal Block with a Compatible Module SCXI-1520 . com Do not loosen or re-orient the safety-ground lug hardware when connecting the safety-ground wire; to do so reduces the safety isolation between the high voltage and safety ground. 00. 4. 04-13-2009 01:49 PM. com relays that switch the resistors in and out of the input circuit to provide shunt calibration and quarter-bridge completion. The SCXI-1304 AC/DC is a shielded terminal block with screw terminals that you can connect to the SCXI-1140, SCXI-1141/1142/1143, SCXI-1120/D, SCXI-1125, or SCXI-1126 input connector. 57 to 0. I kept two load cells of 100 tonne capacity each of the same make one above the another between the cross heads of the UTM. LK - 29 Aug. This module features software-selectable voltage excitation, multiple lowpass filters, and over 40 input gain settings. When you configure your SCXI-1520 in Measurement & Automation Explorer (MAX) you can also assign an accessory such as the SCXI-1314T to the module. Enter the path to the updated Remote SCXI image file and click OK. 0. B-2 B. National Instruments SCXI-1520 8 Channel Universal SCXI Strain Gage Input Module. Within daqmx I have my range set for -500 to 3500 uStrain with an excitation of 10V and gage factor of 2. I connected two 1. Open a service request. 6 pages. arinc & 1553 . SCXI-1317 Circuit Parts Location Diagram 6. Mod4: SCXI-1520 w/ SCXI-1314. I'd like to know if it's possible to do a hardware synchronization between SCXI-1600 and a "PCMCIA CAN/2 series2"? I have the cable to connect the PCMCIA connector "sync" to the PFI7 and PFI0 of the SCXI-1600, but in Labview, when I select the Dev1/PFI7 as source of "DAQmx Timing. Each group corresponds to one of the eight channels available. I would also like to mention that the 2nd module had also the same problem with the 2nd similar chassis. Some hardware accessories may not yet reflect the NI-DAQmx terminal names shown here.